mysql5.7.19 迁移数据库失败

在服务器的 mysql 版本是 mysq l5.7.19,迁移后 mysql 日志内容如下

重点是这里

2017-09-29T13:24:30.716454+08:00 60 [Warning] Timeout waiting for reply of binlog (file: mysql-bin.000002, pos: 1699), semi-sync up to file , position 0.

这说明 BINLOG 未开启,检查 BINLOG 是否开启

mysql> show variables like 'log_%'
-> ;
+----------------------------------------+---------------------+
| Variable_name | Value |
+----------------------------------------+---------------------+
| log_bin | OFF |
| log_bin_basename | |
| log_bin_index | |
| log_bin_trust_function_creators | OFF |
| log_bin_use_v1_row_events | OFF |
| log_builtin_as_identified_by_password | OFF |
| log_error | /var/log/mysqld.log |
| log_error_verbosity | 3 |
| log_output | FILE |
| log_queries_not_using_indexes | OFF |
| log_slave_updates | OFF |
| log_slow_admin_statements | OFF |
| log_slow_slave_statements | OFF |
| log_statements_unsafe_for_binlog | ON |
| log_syslog | OFF |
| log_syslog_facility | daemon |
| log_syslog_include_pid | ON |
| log_syslog_tag | |
| log_throttle_queries_not_using_indexes | 0 |
| log_timestamps | UTC |
| log_warnings | 2 |
+----------------------------------------+---------------------+
21 rows in set (0.01 sec)

发现值为 OFF

编辑 my.cnf

vim /etc/my.cnf
[mysqld]
log-bin=mysql-bin
server-id=1

重启

service mysql.server start

报错

dump data error: [Reason: 2017-09-29 14:42:14 [ERROR] - Could not exec:select * from information_schema.GLOBAL_STATUS where VARIABLE_NAME='Threads_running', return:The 'INFORMATION_SCHEMA.GLOBAL_STATUS' feature is disabled; see the documentation for 'show_compatibility_56' 2017-09-29 14:42:19 [ERROR] - Could not exec:select * from information_schema.GLOBAL_STATUS where VARIABLE_NAME='Threads_running', return:The 'INFORMATION_SCHEMA.GLOBAL_STATUS' feature is disabled; see the documentation for 'show_compatibility_56' 2017-09-29 14:42:24 [ERROR] - Could not exec:select * from information_schema.GLOBAL_STATUS where VARIABLE_NAME='Threads_running', return:The 'INFORMATION_SCHEMA.GLOBAL_STATUS' feature is disabled; see the documentation for 'show_compatibility_56' 2017-09-29 14:42:29 [ERROR] - Checking MySQL workload failed, please retry later ]

解决方法是配置文件增加后重启

show_compatibility_56=ON